| Company Name: |
Tianjin heowns Biochemical Technology Co., Ltd.
|
| Tel: |
400 638 7771 |
| Email: |
sales@heowns.com |
| Products Intro: |
Product Name:PotassiuM tetrakis(4-tert-butylphenyl)borate CAS:401818-78-8 Purity:95% Package:1g;5g;25g;100g;500g;1000g
|
| Company Name: |
Tianjin heowns Biochemical Technology Co., Ltd.
|
| Tel: |
400-6387771-6039 18920764717 |
| Email: |
sales@heowns.com |
| Products Intro: |
Product Name:Potassium tetrakis(4-tert-butylphenyl)borate CAS:401818-78-8 Purity:95% Package:0.25g;1g
|
| Company Name: |
Guangdong wengjiang Chemical Reagent Co., Ltd.
|
| Tel: |
0751-2815987 13927875076 |
| Email: |
3007432263@qq.com |
| Products Intro: |
Product Name:Potassiumtetrakis(4-tert-butylphenyl)borate CAS:401818-78-8 Purity:>=95.0% Package:100mg
|
| Company Name: |
Santa Cruz Biotechnology Inc
|
| Tel: |
021-60936350 |
| Email: |
scbt@scbt.com |
| Products Intro: |
Product Name:Potassium tetrakis(4-tert-butylphenyl)borate CAS:401818-78-8
|
|
| | POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE Basic information | | Uses Application |
| | POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE Chemical Properties |
| | POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE Usage And Synthesis |
| Uses | It can be used to prepare enantiomeric potential sensors based on potassium tetrakis(4-tert-butylphenyl)borate. It can be used for the identification and detection between two enantiomers. | | Application | CN201310686828 reports an enantiomeric potentiometer based on potassium tetra(4-tert-butylphenyl)borate, which is prepared by the following steps: (1) Weigh 3-4 parts by weight of potassium tetra(4-tert-butylphenyl)borate, 64-66 parts by weight of plasticizer and 32-33 parts by weight of PVC, and dissolve them in 600 parts by weight of tetrahydrofuran; (2) After all components are completely dissolved, pour the solution onto a glass plate and allow it to spread naturally. After standing at room temperature for 23-25 hours, a PVC film is obtained; (3) The obtained PVC film is... The membrane was attached to one end of a PVC hollow tube with a PVC concentration of 8% tetrahydrofuran solution. After 10 minutes, the solvent was completely evaporated and KCl was poured into the tube. An Ag/AgCl internal reference electrode was inserted to obtain a PVC membrane electrode. (4) The PVC membrane electrode and the calomel electrode were combined to form an enantiomeric potential sensor. The sensor expression is as follows: Hg-Hg2Cl2︱KCl(satd.)|test solution︱PVC membrane︱0.1mol·L-1KCl|AgCl-Ag. |
| | POTASSIUM TETRAKIS(4-TERT-BUTYLPHENYL)BORATE Preparation Products And Raw materials |
|