ChemicalBook--->CAS DataBase List--->1240398-14-4

1240398-14-4

1240398-14-4 Structure

1240398-14-4 Structure
IdentificationBack Directory
[Name]

Leukotriene E4-d5
[CAS]

1240398-14-4
[Synonyms]

Leukotriene E4-d5
OTZRAYGBFWZKMX-XPGOKVCBSA-N
Leukotriene E4-d5 MaxSpecStandard
[Molecular Formula]

C23H37NO5S
[MDL Number]

MFCD10567081
[MOL File]

1240398-14-4.mol
[Molecular Weight]

439.61
Chemical PropertiesBack Directory
[storage temp. ]

Store at -80°C
[solubility ]

DMF: >50 mg/ml,DMSO: >50 mg/ml,Ethanol: >50 mg/ml,PBS (pH 7.2): >100 μg/ml
[form ]

Liquid
[color ]

Colorless to light yellow
Safety DataBack Directory
[Symbol(GHS) ]


GHS02,GHS08
[Signal word ]

Danger
[Hazard statements ]

H225-H350
[Precautionary statements ]

P201-P202-P210-P233-P240-P241-P242-P243-P280-P303+P361+P353-P308+P313-P370+P378-P403+P235-P405-P501
Hazard InformationBack Directory
[Description]

Leukotriene E4-d5 (LTE4-d5) is intended for use as an internal standard for the quantification of LTE4 by GC- or LC-mass spectrometry. LTE4 is produced by the action of dipeptidase on LTD4, leaving only the cysteinyl group still attached to the fatty acid backbone. It is one of the constituents of slow-reacting substance of anaphylaxis (SRS-A). LTE4 is considerably less active (8 to 12-fold) than LTC4 in the biological activities characteristic of cysteinyl leukotrienes. Unlike LTC4 and LTD4, LTE4 accumulates in both plasma and urine. Therefore, urinary excretion of LTE4 is most often used as an indicator of asthma. In humans, basal levels of LTE4 range from 1-100 pg/mg creatinine. In asthmatic patients, urinary LTE4 levels increase to 80-1,000 pg/mg creatinine.

LTE4-d5 MaxSpec® standard is a quantitative grade standard of LTE4-d5 (Item No. 10007858) that has been prepared specifically for mass spectrometry or any application where quantitative reproducibility is required. The solution has been prepared gravimetrically and is supplied in a deactivated glass ampule sealed under argon. The concentration was verified by comparison to an independently prepared calibration standard. This LTE4-d5 MaxSpec® standard is guaranteed to meet identity, purity, stability, and concentration specifications and is provided with a batch-specific certificate of analysis. Ongoing stability testing is performed to ensure the concentration remains accurate throughout the shelf life of the product. Note: The amount of solution added to the vial is in excess of the listed amount. Therefore, it is necessary to accurately measure volumes for preparation of calibration standards. Follow recommended storage and handling conditions to maintain product quality.
[Uses]

Leukotriene E4-d5
[storage]

Store at -80°C
[References]

[1] K BERNSTR?M  S H. Metabolism of leukotriene D by porcine kidney.[J]. The Journal of Biological Chemistry, 1981, 256 18: 9579-9582.
[2] MALMSTEN C L. Leukotrienes: mediators of inflammation and immediate hypersensitivity reactions.[J]. Critical Reviews in Immunology, 1984, 4 4: 307-334.
[3] LEFER A M. Leukotrienes as mediators of ischemia and shock[J]. Biochemical pharmacology, 1986, 35 2: Pages 123-127. DOI: 10.1016/0006-2952(86)90502-2
[4] M. KUMLIN. Validation and application of a new simple strategy for measurements of urinary leukotriene E4 in humans[J]. Clinical and Experimental Allergy, 1995, 25 5: 467-479. DOI: 10.1111/j.1365-2222.1995.tb01079.x
[5] J M DRAZEN. Recovery of leukotriene E4 from the urine of patients with airway obstruction.[J]. The American review of respiratory disease, 1992, 146 1: 104-108. DOI: 10.1164/ajrccm/146.1.104
[6] M KUMLIN. Urinary excretion of leukotriene E4 and 11-dehydro-thromboxane B2 in response to bronchial provocations with allergen, aspirin, leukotriene D4, and histamine in asthmatics.[J]. The American review of respiratory disease, 1992, 146 1: 96-103. DOI: 10.1164/ajrccm/146.1.96
[7] LAURENCE BALAS*. Rapid Metabolization of Protectin D1 by β-Oxidation of Its Polar Head Chain[J]. Journal of Medicinal Chemistry, 2019, 62 21: 9961-9975. DOI: 10.1021/acs.jmedchem.9b01463
[8] NAN LIN. Myeloid Cell Hypoxia-Inducible Factors Promote Resolution of Inflammation in Experimental Colitis.[J]. Frontiers in Immunology, 2018: 2565. DOI: 10.3389/fimmu.2018.02565
1240398-14-4 suppliers list
Company Name: ChemeGen(Shanghai) Biotechnology Co.,Ltd.  
Tel: 18818260767
Website: http://www.chemegen.com
Company Name: Energy Chemical  
Tel: 021-58432009 400-005-6266
Website: http://www.energy-chemical.com
Company Name: amyjetsci  
Tel: 027-59626688 18771149750
Website: https://www.amyjet.com/
Company Name: CHINA ISOTOPE CO., LIMITED  
Tel: 13062666369
Website: https://www.isotopechem.com/
Company Name: Shanghai Yifei Biotechnology Co. , Ltd.  
Tel: 021-65675885 18964387627
Website: http://www.efebio.com
Company Name: Shanghai Aladdin Biochemical Technology Co.,Ltd.  
Tel: 400-6206333 13167063860
Website: www.aladdin-e.com/
Company Name: Cayman Chemical Company  
Tel: 800-364-9897
Website: www.caymanchem.com
Company Name: Santa Cruz Biotechnology Inc  
Tel: 021-60936350
Website: www.scbt.com
Company Name: Neobioscience Co., Ltd.  
Tel: 4006-800-892
Website: www.nbs-bio.com
Company Name: Absin Bioscience Inc.  
Tel: 021-38015121-8802
Website: http://www.absin.cn
Company Name: Cayman Chemical Company  
Tel: (800) 364-9897
Website: www.caymanchem.com
Company Name: United States Biological  
Tel: 800.520.3011 or 781.639.5092
Website: www.usbio.net
Company Name: Shanghai Hao Zhun Biological Technology Co., Ltd.  
Tel: 15800340161
Website: www.zzsrm.com
Company Name: Guangzhou Boshao Biotechnology Co., Ltd.  
Tel: 18665625935
Website: www.chemicalbook.com/ShowSupplierProductsList1622036/0_EN.htm
Company Name: Shanghai Hongyu Biotechnology Co., Ltd.  
Tel: 02158116080
Website: www.chemicalbook.com/ShowSupplierProductsList788687/0_EN.htm
Tags:1240398-14-4 Related Product Information

  • HomePage | Member Companies | Advertising | Contact us | Previous WebSite | MSDS | CAS Index | CAS DataBase | Privacy | Terms | About Us
  • All products displayed on this website are only for non-medical purposes such as industrial applications or scientific research, and cannot be used for clinical diagnosis or treatment of humans or animals. They are not medicinal or edible.
    According to relevant laws and regulations and the regulations of this website, units or individuals who purchase hazardous materials should obtain valid qualifications and qualification conditions.
  • Copyright © 2023 ChemicalBook All rights reserved.